20.1203—Determination of external dose from airborne radioactive material.
               		
               		
               	 	
               	 	
               	 	
               	 		
    
         Licensees shall, when determining the dose from airborne radioactive material, include the contribution to the deep-dose equivalent, lens dose equivalent, and shallow-dose equivalent from external exposure to the radioactive cloud (see appendix B to  part 20, footnotes 1 and 2).
     
    
        
            Code of Federal Regulations
        
        
            Note:
            Airborne radioactivity measurements and DAC values should not be used as the primary means to assess the deep-dose equivalent when the airborne radioactive material includes radionuclides other than noble gases or if the cloud of airborne radioactive material is not relatively uniform. The determination of the deep-dose equivalent to an individual should be based upon measurements using instruments or individual monitoring devices.
            
        
    
    
        
            Code of Federal Regulations
        