7.69—Approval marking.
               		
               		
               	 	
               	 	
               	 	
               	 		
    
         Each approved blasting unit shall be identified as permissible by a legible and permanent marking securely attached, stamped, or molded to the outside of the unit. This marking shall include the following:
    
    
        
        (a) 
         The assigned MSHA approval number.
     
    
        
        (b) 
         The maximum blasting circuit resistance.
     
    
        
        (c) 
         A warning that the unit's components must not be disassembled or removed.
     
    
        
        (d) 
         The replacement battery types if the unit has replaceable batteries.
     
    
        
        (e) 
         A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used.
     
    
        
        (f) 
         A warning that the unit is compatible only with detonators that will—
     
    
        
        (1) 
         Fire when an average of 1.5 amperes is applied for 5 milliseconds;
     
    
        
        (2) 
         Not misfire when up to an average 100 amperes is applied for 10 milliseconds; and
     
    
        
        (3) 
         Not fire when a current of 250 milliamperes or less is applied.