183.114—Test of flotation materials.
        
        (a) Vapor test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed in a fully saturated gasoline vapor atmosphere for 30 days at a minimum temperature of 38 °C.
    
    
        
        (b) 24-hour gasoline test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 °C in reference fuel B, of ASTM D 471 (incorporated by reference, see  § 183.5 ).
    
    
        
        (c) 30-day gasoline test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 °C in reference fuel B, of ASTM D 471 (incorporated by reference, see  § 183.5 ).
    
    
        
        (d) 24-hour oil test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 °C in reference oil No. 2, of ASTM D 471 (incorporated by reference, see  § 183.5 ).
    
    
        
        (e) 30-day oil test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 °C in reference oil No. 2, of ASTM D 471 (incorporated by reference, see  § 183.5 ).
    
    
        
        (f) 24-hour bilge cleaner test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 °C in a 5-percent solution of trisodium phosphate in water.
    
    
        
        (g) 30-day bilge cleaner test.
         The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 °C in a 5-percent solution of trisodium phosphate in water.
    
    
        
        (h) 
         The buoyant force reduction in paragraphs (a) through (g) of this section is measured in accordance with ASTM D 2842 (incorporated by reference, see  § 183.5 ).
    
    | Test 183.114 | Area 183.110 | ||
|---|---|---|---|
| (b) Engine room bilge | (c) Engine room unless open to atmosphere | (d) Bilge | |
| (a) Vapor test | X | ||
| (b) 24 hour gasoline test | X | ||
| (c) 30 day gasoline test | X | ||
| (d) 24 hour oil test | X | ||
| (e) 30 day oil test | X | ||
| (f) 24 hour bilge cleaner test | X | ||
| (g) 30 day bilge cleaner test | X | ||