1065.265—Nonmethane cutter.
        
        (a) Application.
         You may use a nonmethane cutter to measure CH4 with a FID analyzer. A nonmethane cutter oxidizes all nonmethane hydrocarbons to CO2 and H2 O. You may use a nonmethane cutter for raw or diluted exhaust for batch or continuous sampling.
    
    
        
        (b) System performance.
         Determine nonmethane-cutter performance as described in  § 1065.365 and use the results to calculate NMHC emission in  § 1065.660.
    
    
        
        (c) Configuration.
         Configure the nonmethane cutter with a bypass line if it is needed for the verification described in  § 1065.365.
    
    
        
        (d) Optimization.
         You may optimize a nonmethane cutter to maximize the penetration of CH4 and the oxidation of  all other hydrocarbons. You may humidify a sample and you may dilute a sample with purified air or oxygen (O2) upstream of the nonmethane cutter to optimize its performance. You must account for any sample humidification and dilution in emission calculations.