1065.284—Zirconia (ZrO2) analyzer.
        
        (a) Application.
         You may use a zirconia (ZrO2) analyzer to measure air-to-fuel ratio in raw exhaust for continuous sampling. You may use O2 measurements with intake air or fuel flow measurements to calculate exhaust flow rate according to  § 1065.650.
    
    
        
        (b) Component requirements.
         We recommend that you use a ZrO2 analyzer that meets the specifications in Table 1 of  § 1065.205. Note that your ZrO2 -based system must meet the linearity verification in  § 1065.307. You may use a Zirconia analyzer that has compensation algorithms that are functions of other gaseous measurements and the engine's known or assumed fuel properties. The target value for any compensation algorithm is 0.0% (that is, no bias high and no bias low), regardless of the uncompensated signal's bias.