147.1803—Existing Class I and III wells authorized by rule—maximum injection pressure.
         The owner or operator shall limit injection pressure to the lesser of:
    
    
    
    Pm = (0.8 − 0.433 Sg) d
    where:
        Pm = injection pressure at the well head in pounds per square inch
        Sg = specific gravity of injected fluid (unitless)
        d = injection depth in feet.