265.1032—Standards: Process vents.
        
        (a) 
         The owner or operator of a fa-cil-ity with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction or -air or steam stripping operations man-aging haz-ard-ous wastes with organic con-cen-tra-tions at least 10 ppmw shall either:
    
    
        
        (1) 
         Reduce total organic emissions from all affected process vents at the facility below 1.4 kg/h (3 lb/h) and 2.8 Mg/yr (3.1 tons/yr), or
    
    
        
        (2) 
         Reduce, by use of a control device, total organic emissions from all affected process vents at the facility by 95 weight percent.
    
    
        
        (b) 
         If the owner or operator installs a closed-vent system and control device to comply with the provisions of paragraph (a) of this section, the closed-vent system and control device must meet the requirements of  § 265.1033.
    
    
        
        (c) 
         Determinations of vent emissions and emission reductions or total organic compound concentrations  achieved by add-on control devices may be based on engineering calculations or performance tests. If performance tests are used to determine vent emissions, emission reductions, or total organic compound concentrations achieved by add-on control devices, the performance tests must conform with the requirements of  § 265.1034(c).
    
    
        
        (d) 
         When an owner or operator and the Regional Administrator do not agree on determinations of vent emissions and/or emission reductions or total organic compound concentrations achieved by add-on control devices based on engineering calculations, the test methods in  § 265.1034(c) shall be used to resolve the disagreement.