118.310—Fire main and hydrants.
        
        (a) 
         Except as required by paragraph (d) of this section, a vessel must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of fire hose.
    
    
        
        (b) 
         Piping, valves, and fittings in a fire main system must comply with  part 119, subpart G of this subchapter.
    
    
        
        (c) 
         Each fire hydrant must have a valve installed to allow the fire hose to be removed while the fire main is under pressure.
    
    
        
        (d) 
         On a vessel carrying more than 600 passengers or with overnight accommodations for more than 49 passengers, the fire main and hydrants must meet  § 76.10-10 of this chapter.
    
    [CGD 85-080, 61 FR 917, Jan. 10, 1996, as amended at 62 FR 51351, Sept. 30, 1997]