170.255—Class 1 doors; permissible locations.
        
        (a) 
         Except as provided in paragraphs (b) and (c) of this section, Class 1 doors within passenger, crew, and working spaces are permitted only above a deck, the molded line of which, at its lowest point at side, is at least 7 feet  (2.14 meters) above the deepest load line.
    
    
    
        
        (1) 
         In the judgment of the OCMI, the door is in a location where it will be closed at all times except when actually in use; and
    
    
        
        (2) 
         The vessel is less than 150 gross tons and will not proceed more than 20 nautical miles (37 kilometers) from shore; or
    
    
    
    
    
    
        
        (d) 
         Quick-acting Class 1 doors are permitted in any location on a vessel that operates on the Great Lakes and is required to meet the damage stability standards of subpart H of  part 172 of this chapter.
    
    
        
        (e) 
         For vessels required to meet the damage stability standards of subpart H of this chapter, when Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7 feet (2.14 meters) above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge.
    
    [CGD 79-023, 48 FR 51010, Nov. 4, 1983, as amended by CGD 80-159, 51 FR 33059, Sept. 18, 1986]