171.067—Treatment of stepped and recessed bulkheads in Type I subdivision.
        
        (1) 
         The main transverse watertight bulkhead immediately forward of a stepped bulkhead is referred to as bulkhead 1; and
    
    
        
        (2) 
         The main transverse watertight bulkhead immediately aft of the stepped bulkhead is referred to as bulkhead 3.
    
    
        
        (b) 
         If a main transverse watertight bulkhead is stepped, it and bulkheads 1 and 3 must meet one of the following conditions:
    
    
    
        
        (i) 
         If the factor of subdivision (FS) determined from  § 171.065 (a) or (b) is greater than 0.9, the distance between bulkheads 1 and 3 must not exceed the maximum separation calculated to demonstrate compliance with  § 171.065.
    
    
        
        (ii) 
         If the factor of subdivision is 0.9 or less, the distance between bulkheads 1 and 3 must not exceed 90% of the floodable length or twice the maximum bulkhead separation calculated to demonstrate compliance with  § 171.065, whichever is smaller.
    
    
        
        (2) 
         Additional watertight bulkheads must be located as shown in Figure 171.067(a) so that distances A, B, C, and D, illustrated in Figure 171.067(a), satisfy the following:
    
    
    
    
        
        (3) 
         The distance A, illustrated in Figure 171.067(b), must not exceed the maximum length determined in  § 171.065 corresponding to a margin line taken 3 inches (7.6 cm) below the step.
    
    
        
        (c) 
         A main transverse bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel a distance A as illustrated in Figure 171.067(c).
    
    
        
        (d) 
         Any part of a recess that lies outside the limits defined in paragraph (c) of this section must be treated as a step in accordance with paragraph (b) of this section.
    
    
        
        (e) 
         The distance between a main transverse watertight bulkhead and the transverse plane passing through the nearest portion of a recessed bulkhead must be greater than the minimum separation specified by  § 171.065(e).
    
    
        
        (f) 
         If a main transverse bulkhead is stepped or recessed, equivalent plane bulkheads must be used in the calculations required to demonstrate compliance with  § 171.065.
    