171.073—Treatment of stepped and recessed bulkheads in Type II subdivision.
        
        (a) 
         A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following:
    
    
        
        (1) 
         A and B must not exceed the maximum bulkhead spacing that permits compliance with  § 171.070; and
    
    
    
        
        (b) 
         A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c).
    
    
        
        (c) 
         If a main transverse watertight bulkhead is recessed or stepped, an equivalent plane bulkhead must be used in the calculations required by  § 171.070.