197.458—Gages and timekeeping devices.
         The diving supervisor shall insure that—
    
    
        
        (a) 
         Each depth gage and timekeeping device is tested or calibrated against a master reference gage or time-keeping device every 6 months;
    
    
        
        (b) 
         A depth gage is tested when a discrepancy exists in a depth gage reading greater than 2 percent of full scale between any two gages of similar range and calibration;
    
    
        
        (c) 
         A timekeeping device is tested when a discrepancy exists in a timekeeping device reading greater than one-quarter of a minute in a 4-hour period between any two timekeeping devices; and