64.47—Type of relief devices.
        
        (a) 
         An MPT with an internal capacity of more than 550 U.S. gallons must have one or more spring loaded relief  valves. In addition, a rupture disc may be attached.
    
    
        
        (b) 
         An MPT with an internal capacity of 550 U.S. gallons or less must have a rupture disc or a spring loaded relief valve.