238.223—Locomotive fuel tanks.
         Locomotive fuel tanks shall comply with either the following or an industry standard providing at least an equivalent level of safety if approved by FRA under  § 238.21 :
    
    
        
        (a) External fuel tanks.
         External locomotive fuel tanks shall comply with the requirements contained in Appendix D to this part.
    
    
        
        (b) Internal fuel tanks.
        
        (1) 
         Internal locomotive fuel tanks shall be positioned in a manner to reduce the likelihood of accidental penetration from roadway debris or collision.
    
    
        
        (2) 
         Internal fuel tank vent systems shall be designed so they do not become a path of fuel loss in any tank orientation due to a locomotive overturning.
    
    
        
        (3) 
         Internal fuel tank bulkheads and skin shall, at a minimum, be equivalent to a 5/16-inch thick steel plate with a yield strength of 25,000 pounds per square inch. Material of a higher yield strength may be used to decrease the required thickness of the material provided at least an equivalent level of strength is maintained. Skid plates are not required.
    
    [67 FR 19991, Apr. 23, 2002]