1065.267—Gas chromatograph.
        
        (a) Application.
         You may use a gas chromatograph to measure CH4 concentrations of diluted exhaust for batch sampling. While you may also use a nonmethane cutter to measure CH4, as described in  § 1065.265, use a reference procedure based on a gas chromatograph for comparison with any proposed alternate measurement procedure under  § 1065.10.
    
    
        
        (b) Component requirements.
         We recommend that you use a gas chromatograph that meets the specifications in Table 1 of  § 1065.205, and it must also meet the linearity verification in  § 1065.307.